• + 7 (700) 356-49-30
    + 86 13431079214
    + 86 17688273501
Siemens Biograph mCT-S64 4R PET/CT
Call Now —
Get Expert Advice

Siemens Biograph mCT-S64 4R

Our hospital has introduced the Siemens Biograph mCT S(64) PET/CT, which integrates the advantages of the latest 52-ring high-definition PET scanner --- high sensitivity, high resolution, high speed, and wide field of view --- with all the functions of a 64-slice spiral CT. Compared with existing PET/CT systems, it offers four major advantages: a wide field of view and high-sensitivity PET acquisition reduce scanning time by more than one-third; reduced radionuclide doses combined with lower CT radiation substantially decrease overall patient exposure; ultra-high-definition image processing enhances resolution and improves image contrast, increasing the detectability of small lesions; and an expanded 78 cm bore significantly improves scanning efficiency and patient comfort. This PET/CT system enables earlier detection of lesions and more precise localization.

Target Population for the Siemens Biograph mCT-S64 4R

Patients requiring PET-CT for diagnostic assistance, staging, restaging, or treatment efficacy evaluation, including but not limited to:

Oncology patients: for detection, localization, diagnosis, staging, and restaging of malignant tumors

Cardiovascular patients: for assessment of cardiac function and myocardial viability

Neurological patients: for brain function evaluation and diagnosis of neurological disorders

Patients requiring radiotherapy planning assistance: for precise delineation and localization of radiotherapy target areas

Interventional radiology patients: for accurate imaging guidance during procedures

Core Features and Advantages

1. Outstanding spatial resolution Full width at half maximum (FWHM) 4.3--7.8 mm, clearly resolving small lesions and providing reliable images for precision diagnosis.

2. High system sensitivity Sensitivity 9.6 kcps/MBq, reducing scan time and patient radiation dose.

3. TOF (Time-of-Flight) technology Integrated TOF technology enhances image signal-to-noise ratio and reduces acquisition time or tracer dose.

4. Continuous bed motion acquisition FlowMotion technology ensures precise bed speed, improving axial sensitivity uniformity.

5. High-performance crystal detectors LSO fast scintillation crystals in a four-ring configuration, axial field of view 22.1 cm, with high counting rate.

6. High noise-equivalent count rate Peak 185 kcps, ensuring stable image quality under high workload conditions.

7. Large bore design 78 cm patient bore facilitates scanning of obese patients and those in special positions

8. 64-slice diagnostic CT Integrated 64-slice CT enables precise PET/CT fusion and localization in a single system.

Call Now —
Get Expert Advice
> Home > Hospital Equipment > PET-CT > Siemens Biograph mCT-S64 4R PET/CT